Maintenance PG 2A / 3A
26 wc_tx000178gb.fm
5 Maintenance
5.1 Maintaining the Emission Control System
Normal maintenance, replacement or repair of emission control
devices and systems may be performed by any repair establishment
or individual; however, warranty repairs must be performed by a
dealer/service center authorized by the engine manufacturer. See the
supplied engine owner’s manual for the applicable emission warranty
information.
5.2 Periodic Maintenance Schedule
The table below lists basic machine maintenance. Tasks designated
with check marks may be performed by the operator. Tasks
designated with square bullet points require special training and
equipment.
Daily
before
starting
After
first
20 hrs.
Every
50
hrs.
Every
100
hrs.
Every
300
hrs.
Check fuel level.
3
Check engine oil level.
3
Inspect air cleaner element.
Replace as needed.
3
Check external hardware.
3
Inspect hoses and housing for leaks.
3
Clean air cleaner element.
Change engine oil.

Clean cooling system.
Check and clean spark plug.
Clean sediment cup.
Check and adjust valve clearance.
Check and adjust impeller clearance.